The Wintriss Store
General Purpose Relay - DPDT 110-120 VAC Coil
2319901
Regular price
$50.00
This general purpose DPDT relay is useful for connecting disparate signals from machine controllers to the ShopFloorConnect Machine Interface's (SMI-2) inputs. The coil operates on 110/120 VAC.
We also offer a version with a 24 VDC coil (part number 2319801) and a DIN rail-mountable socket for this relay (part number 2320001).
Specifications
Coil volatge | 110-120 VAC | |
Rated coil current (mA) | 50 Hz | 9.9 @ 110 VAC, 10.8 @ 120 VAC |
60 Hz | 8.4 @ 110 VAC, 9.2 @ 120 VAC | |
Coil resistance | 50µΩ max. | |
Coil Inductance | Armature OFF | 0.69 H |
Armature ON | 1.3 H | |
Must-operate coil voltage | 80% max. | |
Must-release coil voltage | 30% min. | |
Maximum coil voltage | 110% of rated voltage | |
Coil power consumption | Approx 1 W at 60 Hz | |
Rated contact load | Resistive load | 5 A at 220 VAC, 5 A at 24VDC |
Inductive load | 2 A at 220 VAC, 2 A at 24VDC | |
Rated contact carry current | 5 A | |
Contact configuration | DPDT | |
Contact structure | Bifurcated | |
Contact materials | AU plating + AG | |
Ambient operating temp. | -55 to 60 degrees C | |
Ambient operating humidity | 5% to 85% | |
Contact resistance*1 | 50µΩmax. | |
Operation time'2 | 20 ms max. | |
Release time | 20 ms max. | |
Max. operating frequency | Mechanical | 18,000 operations/h |
Rated load | 1,800 operations/h | |
Insulation resistance | 100 MQ min. | |
Dielectric strength | Between coil and contacts | 2,000 VAC at 50/60Hz for 1 min. |
Between contacts of the same polarity | 2,000 VAC at 50/60Hz for 1 min. | |
Between contacts of different polarity | 1,000 VAC at 50/60Hz for 1 min. | |
Vibration resistance | Destruction | 10 to 55 to 10Hz, 0.5-mm single amplitude (1.0-mm double amplitude) |
Malfunction | 10 to 55 to 10Hz, 0.5-mm single amplitude (1.0 -mm double amplitude) | |
Shock resistance | Destruction | 1,000 m/s2 |
Malfunction | 200 m/s2 | |
Endurance | Mechanical | 50,000,000 operations minimum (at operating frequency: 18,000 operations/h) |
Electrical | 200,000 operations minimum (at rated load, switching frequency: 1,800 operaitons/h) |